PC-3000 high resolution 5-channel multi-parameter monitor Multi-parameter monitors Gima 35134
  • New
PC-3000 high resolution 5-channel multi-parameter monitor Multi-parameter monitors Gima 35134
PC-3000 high resolution 5-channel multi-parameter monitor Multi-parameter monitors Gima 35134 PC-3000 high resolution 5-channel multi-parameter monitor Multi-parameter monitors Gima 35134 PC-3000 high resolution 5-channel multi-parameter monitor Multi-parameter monitors Gima 35134

PC-3000 high resolution 5-channel multi-parameter monitor

PC 3000 Multi Parametric Monitor with 5-channel high resolution display.

€1,525.00
VAT included
€1,250.00 VAT Excl.
Quantity
In Stock

help_outlineINFO E PREVENTIVI
PC-3000 high resolution 5-channel multi-parameter monitor

PC-3000 high resolution 5-channel multi-parameter monitor

 

  Are you in UK or outside Euro Zone?

You will not pay Italian 22% VAT

  Are you a Doctor or a Professional?

Sign in here to obtain reserved price list

  Fast shipping throughout Europe

We use only premium couriers

PC 3000 Multi Parametric Monitor with 5-channel high resolution display.

- 7'' high resolution TFT color display, with 5 channel display (various parameter display modes available)

- Standard parameters: ECG, RESP, SpO2, NIBP, 2-TEMP, PR;

- Arrhythmia analysis and ST segment analysis

- Store up to 800 sets of data and 24 hours of ECG traces

- 480 hour graphic and tubular trend for all parameters

- Display shows 7 ECG channels simultaneously

- Protection against interference from defibrillation/electrosurgery

- Adult/pediatric measurement mode

- Visual and audible alarms



Technical features

NIBP monitoring

• Measurement method: Automatic measurement by oscillation method

• Cuff inflation time: <30 seconds (typical adult cuff)

• Initial cuff inflation pressure: Adult and pediatric model: 180mmHg

• Overpressure protection limit: Adult and pediatric model: 300mmHg

Measuring range

• Systolic blood pressure: Adults and children: 25mmHg – 265mmHg

• Diastolic blood pressure: Adults and children: 12mmHg – 220mmHg

• Mean arterial pressure: Adults and children: 18mmHg – 245mmHg

• Measurement accuracy: Systolic +- 10% Diastolic +- 10% MAP +- 10%

• Measurement modes: Manual, Automatic, STAT

• Automatic measurement: 1-240 min

Intervals: Interval tolerance: <10s

TEMP. monitoring

• Measuring range, accuracy: 15°C – 45°C, +-0.2°C

SpO2 & Pulse Rate Monitoring

• Dual wavelength LED transducer

• SpO2 measurement range 35%-100%

• Low perfusion capacity 0.4% - 5%

• SpO2 display accuracy: 90%~99% ±2%, 70%~89% ±4%, 40%~69% ±6%

• PR measurement range: 30bpm~250bpm

• PR measurement accuracy: ±2bpm

ECG monitoring

• Heart rate measurement: ±0.4mVp~±3mVp

• Heart rate display range: 20bpm~250bpm

• Display accuracy: ±1% or ± 2 bpm, whichever is greater

• Heart rate delay time alarm: =12s

• Sensitivity selection: Auto, ×1/2, ×1, ×2, ×4 tolerance: =5%

• Speed: 12.5 mm/s, 25mm/s, 50mm/s tolerance: =10%

• ECG noise level: =30µVP-P

• Input ECG current: =0.1µA

• Input impedance: =5MO

• Time constant Monitoring mode

• Diagnostic mode

• Response Rate Monitoring Mode

• Diagnostic mode

RESP monitoring

• Measuring range, accuracy: 0rpm~120rpm, ±10%

• RESP alarm range: 0bpm~100bpm

• Alarm tolerance: ±10%



Other technical features

• Power supply: 100~250Vac, 50/60Hz

• Consumption: <80 VA

• 1.2 inch display, color TFT LCD

• Alarm mode Visual-acoustic alarms

• Ethernet network port

Standard equipment

1 ECG cable

1 adult SpO2 probe

1 AC power adapter

1 Li-ion battery

1 NIBP cuff

1 Body surface temperature sensor

10 disposable electrodes

1 Power cable, user manual

35134

Data sheet

CE Certification:
Yes