DIATERMO MB 400D HOSPITAL - mono-bipolar 400 Watt Electrosurgery Units Gima 30634
  • New
DIATERMO MB 400D HOSPITAL - mono-bipolar 400 Watt Electrosurgery Units Gima 30634

DIATERMO MB 400D HOSPITAL - mono-bipolar 400 Watt

MB 400D is a high frequency electrosurgical unit that can be used to simultaneously perform monopolar and bipolar surgery.

€7,442.00
VAT included
€6,100.00 VAT Excl.
Quantity
In Stock

help_outlineINFO E PREVENTIVI
DIATERMO MB 400D HOSPITAL - mono-bipolar 400 Watt

DIATERMO MB 400D HOSPITAL - mono-bipolar 400 Watt

 

  Are you in UK or outside Euro Zone?

You will not pay Italian 22% VAT

  Are you a Doctor or a Professional?

Sign in here to obtain reserved price list

  Fast shipping throughout Europe

We use only premium couriers

High frequency electrosurgical unit that can be used to simultaneously perform monopolar and bipolar surgery.

DOUBLE OPERATIONAL ACTIVITY

- two output channels for monopolar cutting

- two independent calibrations and channels for the most frequent monopolar coagulations

CONTROLLED CUTTING PROCEDURES

- intensified cutting currents for incisions without eschar

- cutting current with coagulating properties for dissection with controlled bleeding

- low capacitive coupling in endoscopic procedures using Slow BLEND current

DOUBLE CONTROLLED COAGULATION PROCEDURES

- SPEEDY coagulation and DEEP coagulation available to 2 operators

- SPRAY coagulation obtainable with handpiece or pedal

BROAD BIPOLAR FEATURES

- bipolar cutting with selectable bleeding control

- slow BLEND cutting currents

- automatic start and stop of coagulation that can be activated separately

TOTAL SAFETY FOR PATIENT AND SURGEON

- acceptability of the contact impedance between the patient's body and the neutral plate continuously verified by the Skin Plate Electronic Control (SPEC)

- continuous monitoring of radio frequency leakage current

- variations in mains voltage automatically compensated before starting the supply of power and radio frequency

CUSTOMIZED PROCEDURES

- independent choice of coagulation currents and power levels of each of the two operators

- ten personal procedures that can be configured and immediately recalled

CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS

- outputs for piloted connections of argon plasma units and fume extractors

AUTOMATIC SELF-DIAGNOSIS

- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of the malfunctions found.

- OUTPATIENT SURGERY

- GENERAL SURGERY

- PEDIATRIC SURGERY

- PLASTIC SURGERY

- THORACIC SURGERY

- VASCULAR SURGERY

- DERMATOLOGY

- ENDOSCOPY

- GASTROENTEROLOGY

- GYNECOLOGY

- NEUROSURGERY

- ORTHOPEDICS

- ENT

- PNEUMOLOGY

- UROLOGY

- VETERINARY

Made in Italy.

Technical features

• Maximum out power monopolar pure CUT: 400 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm

• Maximum out power monopolar cut ENHANCED: 250 W - 500 Ohm

• Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm

• Maximum out power monopolar coag SPEEDY: 120 W - 500 Ohm

• Maximum out power monopolar coag DEEP: 120 W - 200 Ohm

• Maximum out power monopolar coag SPRAY 100 W - 2000 Ohm

• Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm

• Maximum out power bipolar CUT 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm

• Working frequency monopolar/bipolar: 425 kHz / 525 kHz

• Patient circuit: F

• Selectable input voltage: 115-230 Vac

• Mains frequency: 50-60 Hz

• Electrical input voltage: 1000 VA

• Size WxHxD: 470 x 150 x 400 mm

• Weight: 17.5 kgs

• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control

• Safety: EN60601-1, EN60601-1-2, EN60601-2-2,

• Electrical Class: I CF, MDD 93/42/EC Class: II b

Standard equipment

1 - 5 m power cable

1 - Autoclavable handpiece with two buttons (30536)

5 - Sterile handpiece cold with two buttons (30551)

1 - Plate cable (30559)

5 - Rem disposable plates (30493)

2 - HP double watertight pedal set

3 - Short blade electrode 7 cm

3 - Blade electrode 16 cm long

3 - Short ball electrode Ø 4 mm, 6 cm

1 - Electrode cleaning sponge

1 - User manual (IT, GB)