MB 200 monopolar bipolar electrosurgical unit 200 W Electrosurgery Units Gima 30542
MB 200 monopolar bipolar electrosurgical unit 200 W Electrosurgery Units Gima 30542 MB 200 monopolar bipolar electrosurgical unit 200 W Electrosurgery Units Gima 30542

MB 200 monopolar bipolar electrosurgical unit 200 W

High frequency electronic electrosurgical units suitable for microcoagulation operations, small and medium monopolar surgery and bipolar coagulation.

€1,769.00
VAT included
€1,450.00 VAT Excl.
Quantity
In Stock

help_outlineINFO E PREVENTIVI
MB 200 monopolar bipolar electrosurgical unit 200 W

MB 200 monopolar bipolar electrosurgical unit 200 W

 

  Are you in UK or outside Euro Zone?

You will not pay Italian 22% VAT

  Are you a Doctor or a Professional?

Sign in here to obtain reserved price list

  Fast shipping throughout Europe

We use only premium couriers

DIATERMO MB200 - mono-bipolar - 200 Watt

The MB 200 high frequency electrosurgical devices allow you to perform medium monopolar or bipolar electrosurgery. The equipment can be used both with a dispensing time equal to the activation time of the output circuit and with an emission time programmable from 1 to 999 thousandths of a second. The programmed current pulse can be single or repeated from 1 to 500 times per second.

The programming of the emission and pause times allows it to be used for biopsy samples, with reduced modification of the sample taken and reduced thermal damage to the tissue being sampled. A particular surveillance circuit for plate-patient contact called Skin Plate Electronic Control safeguards the patient from the risk of burns due to the casual detachment of the reference plate.

The available waveforms and the values of the peak voltages used, as well as the accurate control of the high frequency leakage currents make the equipment particularly suitable for use in endoscopic surgery, for procedures such as polypectomy, prostatic resection (TURP), papillectomy, uterine resection, endometrial ablation, etc. Coagulation can be performed with a high crest factor current, to obtain a high thermal effect, or with a low crest factor current, to obtain coagulation in the absence of carbonization.

Technical features

• Minimum selectable power: 0
• Power step: 1
• Maximum CUT cutting power (W): 200 - 250 ohm
• Maximum cutting power CUT 90% (W): 200 - 250 ohm
• Maximum cutting power CUT 80% (W): 200 - 250 ohm
• Maximum cutting power CUT 70% (W): 200 - 250 ohm
• Maximum cutting-coagulated BLEND power (W): 120 - 200 ohm
• COAG FORCED maximum coagulation power (W): 150 - 150 ohm
• COAG SOFT maximum coagulation power (W): 90 - 100 ohm
• Maximum bipolar power BIPOLAR (W): -
• Maximum bipolar power BIPOLAR COAG (W): 100 - 100 ohm
• Maximum bipolar power BIPOLAR CUT (W): 120 - 250 ohm
• CUT Crest Factor: 1.5
• CUT 90% Crest Factor: 1.6
• CUT 80% Crest Factor: 1.7
• CUT 70% Crest Factor: 1.8
• BLEND Crest Factor: 2.1
• FORCED COAG Crest Factor: 2.0
• COAG SOFT Crest Factor: 1.7
• BIPOLAR Crest Factor: -
• BIPOLAR CUT Crest Factor: 1.5
• Working frequency: 600 kHz
• Weight: 8 kg
• Dimensions WxHxD: 360 x 150 x 265 mm
• Power supply: 115/230V - 50/60 Hz selectable
• Fuses for power supply: 230 Vac (5x20) Time-delayed 2x 3.15A
• Fuses for power supply: 115 Vac (5x20) Time-delayed 2x 6.3A
• Sound emission: adjustable in 5 steps (from 55- to 75dBA)
• Self-diagnosis of faults
• Control of the power emitted
• Possibility of connecting single and split electrodes
• Timed emission: 1-999ms
• Storage of last used settings
• Electrical classification (EN60601-1) I CF
• MDD classification 93/42/EEC IIB
• Neutral electrode F
• Duty cycle (action/pause) in seconds: 10/30

Standard equipment

• Autoclavable 2-button handpiece (30536)
• MB 30577 watertight pedal (alternative to using the handpiece)
• Metal plate with cable 30564
• Kit of 10 standard short electrodes Ø 2.4 mm
• 2 m power cable
• Manual: available in English, French, Italian
30542