K15 touchscreen ECG multi-parameter monitor with 5 leads
Multifunctional monitor to monitor the vital physiological signs of adult, pediatric and neonatal patients.
You will not pay Italian 22% VAT
Sign in here to obtain reserved price list
We use only premium couriers
K15 TOUCHSCREEN 15" MULTIPARAMETRIC MONITOR - with 5-lead ECG
Multifunctional monitor to monitor the vital physiological signs of adult, pediatric and neonatal patients.
With real-time recording and display functions of parameters such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it enables analysis complete assessment of the patient's physiological conditions.
- ergonomic design with intuitive user interface
- USB socket for data transfer and software updating
- 9 tracks on video waveforms
- Windows style environment, easy to use
- visual and audible alarm for physiological and technical anomalies
- large memory capacity
- suitable for use with original Nellcor sensors
- protection against defibrillator discharges, resistance against interference from electrosurgical units; detection and inhibition of cardiac pacemaker impulses.
PC software GB, IT, ES. Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU.
Compatible with Windows XP, 7, 8, 10, 11.
Technical features
ECG
Input dynamic range: ±(0.5~5 mVp)
Differential input impedance: =10 MO
Bandwidth: 0.05~150Hz (Diagnostics), 0.5~40Hz (Monitoring), 1~20Hz (Operation)
CMRR: =90 dB (Diagnostics) / =105 dB (Monitoring & Operation)
Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
Scanning speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater
Pacemaker pulse detection and inhibition function
RESP
Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater
TEMP
Measuring range: 21.0~50.0°C ±0.2°C between 25~45°C
NIBP
Technique: Oscillometric method
Typical measurement time: <30 seconds (adult cuff)
NIBP measurement range: SYS: 40~275 mmHg (Adult) / 40~200 mmHg (Pediatric) / 40~135 mmHg (Neonatal)
NIBP measurement range: DIA: 10~210 mmHg (Adult) / 10~150 mmHg (Pediatric) / 10~95 mmHg (Neonatal)
NIBP measurement range: MAP: 20~230 mmHg (Adult) / 20~165 mmHg (Pediatric) / 20~110 mmHg (Neonatal)
NIBP measurement accuracy: Mean difference: ±5 mmHg
Standard deviation: 8 mmHg
Measurement mode NIBP: Manual, Auto, STAT, Multicycle
Self-measurement intervals: 1-480 min
SpO2
Technique: Dual wavelength optical method
Measurement range: 0%~100% ±2% for SpO2 range 70~100%
PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater
Low perfusion efficiency: Up to 0.3%.
Other characteristics
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA
- Built-in lithium battery: 11.1V/4400 mAh
- Screen: 12 or 15 inch TFT screen
- Alarm method: 3-level audible-visual alarm
- Network: Ethernet
- Safety Standard: IEC 60601-1
Standard equipment
- Adult SpO2 probe
- Adult NIBP cuff
- SpO2 extension cable
- ECG cable
- Skin temperature probe
- Power cord
- Rechargeable lithium battery
- Dust cover
- Disposable electrode
- Manual: GB, FR, IT, ES,